Advanced electrical test instruments Vanguard

Vanguard ATRT-03 S2 Three-Phase Transformer Turns Ratio Tester

ATRT-03 S2

ATRT-03 S2 Three-Phase Transformer Turns Ratio Tester

The ATRT-03 S2 can be used as a standalone unit or can be computer-controlled. It can be operated locally using its alpha-numeric keypad and rotary switch. Information is displayed on a back-lit LCD screen (128 x 64 pixels) that.

M2K engineers testing a distribution transformer with Vanguard instruments at Energypac

Overview

The ATRT-03 S2 can be used as a standalone unit or can be computer-controlled. It can be operated locally using its alpha-numeric keypad and rotary switch. Information is displayed on a back-lit LCD screen (128 x 64 pixels) that is viewable in both bright sunlight and low-light levels. Test reports can be printed in the field on the unit's built-in 4.5-inch wide thermal printer. The ATRT-03 S2 is capable of storing up to 112 test records and 128 test plans in Flash EEPROM memory. Test records or test plans can be.

The ATRT-03 S2 is Vanguard's third generation, microprocessor-based, automatic, three phase, transformer turns-ratio tester. This lightweight and rugged portable unit is designed for transformer testing at utility power substations. The ATRT-03S2 determines the transformer turns-ratio using the IEEE C57.12.90 measurement method. The ATRT-03 S2 outputs an excitation test voltage to the transformer's primary windings. The induced secondary voltage is sensed and the transformer turns-ratio is calculated. The ATRT-03.

To prevent an accidental wrong test-lead hook-up (e.g., when the operator reverses H and X leads), the ATRT-03 S2 outputs a low-level test voltage to verify the hook-up condition before applying the full test voltage to the transformer. Three test voltages (8 Vac, 40 Vac, 100 Vac) allow the ATRT-03 S2 to test CT's and PT's, as well as power transformers. Auto-Detect Transformer Configuration The ATRT-03 S2 can automatically detect 130 specific vector groups for different transformer types defined by ANSI, CEI/IEC.

Key capabilities

  • Ratio range: 0.8 ¬ 15,000 : 1
  • Capable of detecting 130 different
  • 3 test voltages: 8Vac, 40Vac, and
  • Phase angle and excitation current measurement
  • RS-232C and USB PC interfaces
  • Optional 4.5" wide thermal printer

Specification

Indicative specification for Vanguard ATRT-03 S2 Three-Phase Transformer Turns Ratio Tester

Indicative specification for guidance. Confirm the current manufacturer datasheet for the configuration being quoted.